Skip to main content
  • Research article
  • Open access
  • Published:

Hydrogel coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms: a meta-analysis of randomized controlled trials

Abstract

Background

Recent studies have shown conflicting results regarding the effect of hydrogel coils for treating intracranial aneurysm compared to bare platinum coils. We implemented a meta-analysis to assess the value of hydrogel coils in intracranial aneurysm treatment.

Methods

The MEDLINE, EMBASE, and Cochrane Library databases were searched for randomized controlled trials (RCTs) which had evaluated hydrogel coils versus bare platinum coils for intracranial aneurysms.

Results

We pooled 1526 patients from 4 RCTs with the mean follow-up time of more than 16 months. Hydrogel coils had reductions on mid-term recurrence (RR 0.78, 95% CI 0.65 to 0.94, P = 0.008) and residual aneurysm (RR 0.71, 95% CI 0.57 to 0.88, P = 0.002), but didn’t show any significant differences in other favorable outcomes such as functional recovery, mortality and so on. In the subgroup analysis, we found that second-generation hydrogel coils might exhibit potential impacts on increasing mid-term complete occlusion (RR 1.26, 95% CI 1.07 to 1.48, P = 0.005) and decreasing residual aneurysm neck. (RR 0.54, 95% CI 0.34 to 0.86, P = 0.010).

Conclusions

Hydrogel coils showed no significant efficacy on functional recovery but exhibited a lower rate of recurrences and residual aneurysms in patients with intracranial aneurysms.

Peer Review reports

Background

Worldwide, intracranial aneurysm, as a life-threatening disease with a high morbidity and mortality rate, brings great economic burdens to both the society and the patient [1]. Intracranial aneurysm is the third most common type of stroke, after ischemic stroke and hypertensive cerebral hemorrhage, which plays the most important role in subarachnoid hemorrhage [2].

Before 1990, neurosurgical operations were the only option for patients with intracranial aneurysm [3]. At 1992, Guglielmi detachable platinum coils(GDC) were introduced as an endovascular treatment which provided patients with an additional treatment option [4,5,6]. Endovascular coil emblization eventually became the preferred modality for many patients, due to better clinical outcomes than neurosurgical clipping in some patients with intracranial aneurysm demonstrated in ISAT(International Subarachnoid Aneurysm Trial) [7]. Although endovascular treatment is a less invasive procedure than neurosurgical aneurysm clipping, patients with endovascular treatment have a higher rate of aneurysm remnant, recurrence and retreatment than patients treated by clipping, in spite of the overall incidence is low [8,9,10,11]. Hence, there still exists a need for improvement in methods of embolization to reduce incomplete occlusion, recurrence, retreatment and post-treatment adverse events [4, 12, 13].

Hydrogel embolic system(HES) is made up of platinum coils covered with cross-linked material, which can absorb much water without dissolving, and presents both liquid-like and solid-like softening behaviors [4, 14]. Therefore, it may provide better efficacy and safety in endovascular treatment. The first-generation hydrogel-coated coils (hydroCoil; MicroVention, Inc., Tustin,CA) [15] were assessed in some clinical trials to compare the clinical outcomes of hydrogel coils and bare platinum coils. These clinical trials include HELPS (Hydrocoil Endovascular aneurysm occLusion and Packing Study) [16] and Poncyljusz’s RCT [17]. HELPS demonstrated that hydrogel coils have a reduction of adverse events and recurrence among intracranial aneurysm patients [18]. In contrast, Poncyljusz’s RCT concluded that hydrogel coils were equally as effective as bare platinum coils [17]. Later, the second-generation hydrogel (Hydrosoft, HydroFrame[3D], MicroVention, Inc) was developed, which was softer, contained less hydrogel, and expanded slower than the first-generation one [19]. In 2018, GREAT(German-French Randomized Endovascular Aneurysm Trial) was established, and some researchers found that compared to bare platinum coils, hydrogel coils decrease the rate of unfavorable outcome events, recurrence, retreatment, morbidity mortality, and need for retreatment in small- and medium-sized intracranial aneurysms [19, 20]. Containing both types of hydrogel coils, PRET 2017(Patients prone to Recurrence after Endovascular Treatment) illustrated that there were no significant differences between hydrogel coils group and bare platinum coils group [21].

Based on the above-mentioned results from previous clinical studies and trials, the efficacy and safety of hydrogel coils treatment for intracranial aneurysm are unclear. Several issues still need to be resolved, including whether or not the use of hydrogel coils reduces incomplete occlusion, complications, adverse events, recurrence, retreatment, morbidity, mortality, etc. We present a meta-analysis of pooled data from previous clinical trials to investigate the value of hydrogel coils treatment for intracranial aneurysm and to explore the potential factors that might influence the efficacy and safety of hydrogel coils.

Methods

Study protocol

A research protocol was drafted following the Cochrane Collaboration format at the beginning of the project [22].

Eligibility criteria

The inclusion criteria were as follows: (a) Type of study: RCT; (b) Language restriction: only available in English; (c) Participating patients: patients with intracranial aneurysms; (d) Intervention: Hydrogel coils or bare platinum coils; (e) Outcomes: complete occlusion, residual neck and residual aneurysm on DSA, excellent outcome (mRS score = 0) and favorable outcome (mRS score = 0–2) based on mRS score, periprocedural complications, major recurrence, retreatment and adverse events. The exclusion criteria were as follows: (a) Types of study: retrospective studies, cohort studies, case reviews and case reports; (b) Control: positive control.

Information sources and search strategy

Three main databases: EMBASE, MEDLINE and Cochrane Library were systematically searched by three authors (TX, ZC and JX). The search strategy was a combination of the variables “coil” AND “intracranial aneurysm” for MEDLINE. Only studies that match the titles and abstracts were searched. The search strategy of Cochrane Library and EMBASE were similar to that search strategy of MEDLINE. In addition, two investigators (TX and ZC) ensured all relevant studies included in the study. They independently manually screened the list of references from the RCTs and systematic reviews.

Study selection and data collection

Two reviewers (TX and ZC) independently assessed all study records from systematic search in systematic reviews and reference lists of RCTs and electronic database on the previously mentioned the eligbility criteria. After the rigorous selection and evaluation of the literature by the two reviewers, the data were extracted from the included RCTs as follows: basic information for included RCTs, inclusion, exclusion criteria, study design and outcome assessments (Table 1).

Table 1 Characteristics of the Included Studies and Outcome Events

Risk of Bias

The risk of bias plot was based on the Review Manager 5.2 software for individual studies. We applied the unified standard of the Cochrane Collaboration to assess the risk of bias of RCTs, which included: selection bias, performance bias, detection bias, attrition bias, reporting bias, and other potential biases.

Summary measures and synthesis of results

The data was assessed by STATA (Version 12.0) software. The risk ratio (relative risk [RR]; 95% confidence interval [CI]) was analyzed using dichotomous outcomes and calculated using a random effect model. Heterogeneity was estimated by the I2 statistic. The I2 statistic as follows: I2 < 30% means “low heterogeneity”; I2 = 30 to 50% denotes “moderate heterogeneity”; I2 > 50% represents “substantial heterogeneity”. Subgroup analyses were implemented to detect different generations hydrogel coils and ruptured rate of aneurysm at baseline. Explore the stability of the consolidated results using sensitivity analysis. A P value of less than 0.05 was considered to be significant and two-tailed tests were implemented for all analyses.

Results

A total of 1256 titles and abstracts were identified through MEDLINE, EMBASE, and Cochrane Library (Fig. 1). After removing the duplicates and irrelevant records, 28 full-text articles were assessed for eligibility. Additionally, 24 articles were excluded as a result of the limitation of publication types: 5 multiple reports on one RCT, 3 post-hoc analysis, 2 meta-analysis, 2 comments, 7 reviews and 5 clinical trials. Ultimately, four RCTs containing 1526 patients (hydrogel, n = 767; bare, n = 759) were included in qualitative synthesis (Fig. 1). The main characteristics of the included studies are listed in Table 1.

Fig. 1
figure 1

The study search, selection, and inclusion process

Outcomes analysis

All 4 RCTs [16, 17, 19, 21] enrolling 1526 patients were pooled for the analysis of periprocedural and mid-term outcome respectively from two aspects of efficacy and safety.

Periprocedural efficacy and safety outcome

There were no significant differences observed in the numbers of patients with initial complete occlusion after endovascular treatment (RR 1.02, 95% CI 0.93 to 1.13, P = 0.679; Fig. 2A) between the hydrogel coil and bare platinum coil groups. Compared with bare platinum coils, hydrogel coils showed no significant differences in preventing periprocedural events, including: failed procedure (RR 1.97, 95% CI 0.68 to 5.76, P = 0.213, Fig. 2B), coil migration (RR 1.53, 95% CI 0.83 to 2.82, P = 0.168, Fig. 2C), perforation (RR 1.25, 95% CI 0.54 to 2.94, P = 0.603, Fig. 2D), hydrocephalus (RR 1.16, 95% CI 0.71 to 1.91, P = 0.555, Fig. 3A) and thromboembolic complications (RR 0.74, 95% CI 0.49 to 1.12, P = 0.148, Fig. 2E). The numbers of periprocedural residual aneurysm neck (RR 0.88, 95% CI 0.76 to 1.02, P = 0.098, Fig. 2F) and residual aneurysm (RR 1.20, 95% CI 0.98 to 1.46, P = 0.080, Fig. 2G) were also similar in the two groups; In addition, morbidity (RR 1.95, 95% CI 0.76 to 5.01, P = 0.167, Fig. 3B) or mortality (RR 1.03, 95% CI 0.26 to 4.16, P = 0.962, Fig. 3C) also showed no significant difference. The heterogeneity of periprocedural mortality is 63.8% with a P value of 0.063 (Fig. 3C). To detect the source of this statistical heterogeneity, a sensitivity analysis was performed. The sensitivity analysis showed that all of the consolidated results were stable (Additional file 1: Figure S1).

Fig. 2
figure 2

The pooled relative risk of the periprocedural efficacy and safety outcome. The diamond indicates the estimated relative risk (95% confidence interval) for all patients together. A, Complete occlusion. B, Failed procedure. C, Coil migration. D, Perforation. E, Thromboembolic complication. F, Periprocedural residual neck. G, Periprocedural residual aneurysm

Fig. 3
figure 3

The pooled relative risk of the periprocedural safety outcomes. The diamond indicates the estimated relative risk (95% confidence interval) for all patients together. A, Hydrocephalus. B, Morbidity. C, Mortality

Mid-term efficacy outcome

Although no significant differences exist in the numbers of mid-term complete occlusion (RR 1.13, 95% CI 0.98 to 1.31, P = 0.094; Fig. 4A), no intracranial aneurysms recurrences in DSA (RR 1.06, 95% CI 0.99 to 1.13, P = 0.106; Fig. 4B) and excellent functional outcome (mRS score = 0) (RR 0.96, 95% CI 0.91 to 1.01, P = 0.150; Fig. 4C) for both groups, bare platinum coils group have an advantage over hydrogel coils group in patients’ good functional outcome(RR 0.97, 95%CI 0.94 to 1.00, P = 0.046, Fig. 4D), which is defined as the follow-up mRS score from 0 to 2. The heterogeneity of mid-term complete occlusion is 49.6% with a P value of 0.138(Fig. 4A). To detect the source of the statistical heterogeneity, a sensitivity analysis was performed. The sensitivity analysis showed that all of the consolidated results were stable (Additional file 1: Figure S2).

Fig. 4
figure 4

The pooled relative risk of the mid-term efficacy outcomes. The diamond indicates the estimated relative risk (95% confidence interval) for all patients together. A, Complete occlusion. B, No IA recurrence in DSA. C, Excellent functional outcome (mRS = 0). D, Good functional outcome (mRS = 0–2)

Mid-term safety outcome

Patients in the hydrogel coils group have a lower rate of mid-term residual neck (RR 0.70, 95% CI 0.49 to 1.01, P = 0.054; Fig. 5A), residual aneurysm (RR 0.71, 95% CI 0.57 to 0.88, P = 0.002; Fig. 5B) and major recurrence (RR 0.78, 95% CI 0.65 to 0.94, P = 0.008; Fig. 5C) than that of the bare platinum coils group. However, this was accompanied by no reduction in the need for retreatment (RR 0.92, 95% CI 0.61 to 1.37, P = 0.675; Fig. 5D), stroke (RR 0.97, 95% CI 0.49 to 1.93, P = 0.934; Fig. 5E), morbidity (RR 1.11, 95% CI 0.73 to 1.69, P = 0.615; Fig. 5E) and mortality (RR 1.49, 95% CI 0.58 to 3.86, P = 0.411; Fig. 5G) after hydrogel coil treatment compared to bare coil treatment. The heterogeneity of Mid-term mortality is 62.0% with P value of 0.072 (Fig. 5G). To detect the source of this statistical heterogeneity, sensitivity analysis was performed. The sensitivity analysis showed that all of the consolidated results were stable (Additional file 1: Figure S3).

Fig. 5
figure 5

The pooled relative risk of the mid-term safety outcomes. The diamond indicates the estimated relative risk (95% confidence interval) for all patients together. A, Mid-term Residual neck. B, Mid-term Residual aneurysm. C, Major recurrence. D, Retreatment. E, Stroke. F, Morbidity (mRS = 3–5). G, Mortality

Subgroup analysis

Subgroup analyses were implemented to assess the influence of different generations of hydrogel coils and ruptured rate of aneurysm at baseline. Second-generation hydrogel coils were more effective in mid-term complete occlusion (RR 1.26, 95% CI 1.07 to 1.48, P = 0.005; Table. 2) and had a lower rate of residual neck (RR 0.54, 95% CI 0.34 to 0.86, P = 0.010; Table. 2). For high ruptured rate subgroup, in which each trial’s proportion of ruptured aneurysms was more than 30%, intracranial aneurysms were more likely to be occluded completely by hydrogel coils than bare platinum coils (RR 1.21, 95% CI 1.07 to 1.38, P = 0.002; Table. 2). The sensitivity analysis demonstrated that all the consolidated statistics were stabilized.

Table 2 Subgroup Analysis of Efficacy and Safety Outcomes

Risk of Bias in included studies

The details of the risk bias for all studies were shown in Fig. 6. There were two clinical trials that have a higher risk of bias in allocation concealment. For the blinding of participants and personnel, the risk of bias was high in one study and the other three trials were unclear. For the blinding of outcome assessment, the risk of bias was high in one study and unclear risk of bias in another trial. For incomplete outcome data, the risk of bias was unclear in one trial. Apart from these four items, there were no high or unclear risk of bias in any of the other items was observed.

Fig. 6
figure 6

Risk of bias: A summary table for each risk of bias item for each study

Discussion

Hydrogel coils embolization for intracranial aneurysm might be superior to bare platinum coils in mid-term outcome based on the evidence from our current meta-analysis. We discovered that hydrogel coils had no distinct benefit in periprocedural efficacy and safety outcomes, including initial post-operational complete occlusion, residual aneurysm neck, residual aneurysm, failed procedure, coil migration, perforation, thromboembolic complication, hydrocephalus, morbidity and mortality, which was in accordance with other studies [4, 9, 16, 17, 19, 21, 23, 24].

Hydrogel coils had a tendency of decreasing mid-term residual aneurysm neck (P = 0.054) and exhibited valid preventions from the mid-term residual aneurysm (P = 0.002). Meanwhile, as a potential tendency of a favorable outcome, no significant differences in the numbers of mid-term complete occlusion were detected (RR 1.13, 95% CI 0.98 to 1.31, P = 0.094). Although the sensitivity analysis demonstrated that the consolidated statistics about mid-term complete occlusion were stabilized, the results might be influenced by the high heterogeneity. Subgroup analyses depicted that second-generation hydrogel coils could improve complete occlusion (P = 0.005) compare to first-generation coils (P = 0.450) when hydrogel coil was detached.

In addition, recurrence was a high-profile and controversial issue among different clinical trials and systematic reviews: HELPS (Hydrocoil Endovascular aneurysm occLusion and Packing Study) [25,26,27], GREAT(German-French Randomized Endovascular Aneurysm Trial) [15, 20] and Serafin’s systematic review [4] illustrated that hydrogel coils resulted in a lower rate of recurrence. In contrast, no significant differences by using hydrogel coils in terms of aneurysm recurrence were observed through Poncyljusz’s RCT [17] and PRET (Patients prone to Recurrence after Endovascular Treatment) [21, 28, 29]. In our meta-analysis, we pooled 1526 patients from 4 RCTs and drew a conclusion that hydrogel coils showed impacts upon avoiding recurrence (RR 0.78, 95% CI 0.65 to 0.94, P = 0.008) against bare platinum coils. Meanwhile, we also found that the number of patients without intracranial aneurysm recurrence in DSA had no distinct difference for the two groups (RR 1.06, 95% CI 0.99 to 1.13, P = 0.106). A hypothesis was established to explain the question that some recurrent patients was not diagnosed with aneurysm recurrence by angiography but through other ways such as CTA, MRA or clinical manifestations [30].

Surprisingly, bare platinum coils group contrarily had an advantage over hydrogel coils group in mid-term patients’ good functional outcome, which is defined as the mRS score from 0 to 2. Why did bare platinum coils group have a favorable result of mid-term patients’ good functional outcome? Although the statistics revealed that hydrogel coils could prevent intracranial aneurysm patients from mid-term residual aneurysm, recurrence; we suspect that it was the degree of damage at the aneurysm ruptured point and post-operational complications that have more influences on the patients’ prognosis which could be measured by mRS score [31]. Hence, we performed a subgroup analyses between high ruptured rate subgroup (N > 30%) and low ruptured rate subgroup (N < 30%). We found no significant differences in good functional outcome when we separated high ruptured rate trials from low ruptured rate trials. Therefore, the favorable outcome of bare platinum coils could be the result of the selection bias of patients in trials and degree of baseline damage patients between hydrogel coils group and bare platinum coils group.

We were also interested in the reasons of why there were no significant differences in initial retreatment (P = 0.675) between the two groups in spite of the fact that bare platinum coils had a distinctly higher rate of recurrence than hydrogel coils (P = 0.008). We found that compared with recurrence, the number of retreatment was obviously smaller and it meant only a part of recurrent patients chose or had a chance to retreat. Therefore, we assumed that the small amount of retreatment was not able to get a statistically significant difference under the circumstance that the number of total patients remained relatively large.

Subgroup analyses indicated that second-generation hydrogel coils could improve complete occlusion and reduce residual aneurysm neck from the results of the mid-term follow-up. We believe it is because that second-generation hydrogel coils were only abundantly employed in GREAT 2018, which could cause the favorable results of hydrogel coils. In the further, when second-generation hydrogel coils are used in more clinical trials, we could get a more reliable outcome of it. The other subgroup analysis found that the high ruptured rate subgroup had a higher probability to get occluded completely. The mechanisms of coils embolization therapy were to form a thrombus in the aneurysm by coils attracting negatively charged blood components (red blood cells, white blood cells and platelets, etc.) to coagulate [32]. Hence, hyperfunction of coagulation system under stress might result in the favorable complete occlusion in high ruptured rate subgroup.

On the basis of our knowledge, it was the first meta-analysis about the comparison between hydrogel coils and bare platinum coils, using evidence solely from RCTs (randomized clinical trials). Previous systematic reviews and meta-analysis were predominantly or entirely based on non-randomized researches [4, 9]. Combining the findings from uncontrolled trials results in a heterogeneous dataset, therefore, these systematic reviews are flawed. Additionally, some systematic reviews and meta-analysis were comprised of not only hydrogel coils but also other bioactive coils [23, 25]. Which resulted in an analysis including mixed types of coil; the outcome of these reviews and meta-analysis inevitable have deviations. In spite of some subgroup analyses about hydrogel coils performed in these research studies [23], the comprehensiveness of the comparison between hydrogel coils and bare platinum coils was insufficient on account of the included trials’ quantity [23]. Different from above-mentioned systematic reviews, all patients in our present meta-analysis were intervened by either hydrogel coils or bare platinum coils in randomized trials, which was the best method to divide risk factors equally over the two groups [33]. Limitations of our meta-analysis should be noticed. First, this meta-analysis was performed on the foundation of limited statistics. We only pooled 4 published RCTs [16, 17, 19, 21] with 1526 patients (hydrogel, n = 767; bare, n = 759) to examine the efficacy and safety of hydrogel coils vs. bare platinum coils for intracranial aneurysm. Additionally, the included RCTs showed heterogeneity in the data of periprocedural mortality (I2 = 63.8%), mid-term mortality (I2 = 62%) and mid-term complete occlusion (I2 = 49.6%). The sensitivity analysis demonstrated that all the consolidated statistics were stabilized, but these disadvantages of the included studies could not be neglected. Lastly, in spite of the patients being randomized in 4 RCTs, the heterogeneous risk factors were still noticeable, and the baseline damage degree or mRS scores between hydrogel coils group and bare platinum coils group might vary patient by patient.

Conclusions

In conclusion, our meta-analysis demonstrated that endovascular treatment for intracranial aneurysms by hydrogel coils had preventive efficacy on mid-term recurrence and residual aneurysm, but didn’t show any significant differences in other outcomes. Second-generation hydrogel coils might exhibit potential favorable impacts on mid-term complete occlusion and residual aneurysm neck, and therefore could affect clinical outcome. Based on our findings, we suggest future researchers to consider testing the possible therapeutic effect of second-generation hydrogel coils in patients with intracranial aneurysms.

Abbreviations

CI:

Confidence interval

DSA:

Digital subtraction angiography

GDC:

Guglielmi detachable platinum coils

GREAT:

German-French Randomized Endovascular Aneurysm Trial

HELPS:

Hydrocoil Endovascular aneurysm occLusion, and Packing Study

HES:

Hydrogel embolic system

ISAT:

International Subarachnoid Aneurysm Trial

mRS:

modified Rankin Scale

PRET:

Patients prone to Recurrence after Endovascular Treatment

RCT:

Randomized controlled trials

RR:

relative risk

References

  1. Solenski NJ, Haley EC Jr, Kassell NF, Kongable G, Germanson T, Truskowski L, Torner JC. Medical complications of aneurysmal subarachnoid hemorrhage: a report of the multicenter, cooperative aneurysm study. Participants of the multicenter cooperative aneurysm study. Crit Care Med. 1995;23(6):1007–17.

    Article  CAS  Google Scholar 

  2. Linn FH, Rinkel GJ, Algra A, van Gijn J. Incidence of subarachnoid hemorrhage: role of region, year, and rate of computed tomography: a meta-analysis. Stroke. 1996;27(4):625–9.

    Article  CAS  Google Scholar 

  3. Molyneux A, Kerr R, International subarachnoid aneurysm trial collaborative G, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. J Stroke Cerebrovasc Dis. 2002;11(6):304–14.

    Article  Google Scholar 

  4. Serafin Z, Di Leo G, Palys A, Nowaczewska M, Beuth W, Sardanelli F. Follow-up of cerebral aneurysm embolization with hydrogel embolic system: systematic review and meta-analysis. Eur J Radiol. 2015;84(10):1954–63.

    Article  Google Scholar 

  5. Gunnarsson T, Klurfan P, terBrugge KG, Willinsky RA. Treatment of intracranial aneurysms with hydrogel coated expandable coils. Can J Neurol Sci. 2007;34(1):38–46.

    Article  Google Scholar 

  6. Bender MT, Wendt H, Monarch T, Lin LM, Jiang B, Huang J, Coon AL, Tamargo RJ, Colby GP. Shifting treatment paradigms for ruptured aneurysms from open surgery to endovascular therapy over 25 years. World neurosurg. 2017;106:919–24.

    Article  Google Scholar 

  7. Molyneux AJ, Birks J, Clarke A, Sneade M, Kerr RS. The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the international subarachnoid aneurysm trial (ISAT). Lancet. 2015;385(9969):691–7.

    Article  Google Scholar 

  8. Zhang X, Li L, Hong B, Xu Y, Liu Y, Huang Q, Liu J. A systematic review and meta-analysis on economic comparison between endovascular coiling versus neurosurgical clipping for ruptured intracranial aneurysms. World neurosurg. 2018;113:269–75.

    Article  Google Scholar 

  9. Rezek I, Mousan G, Wang Z, Murad MH, Kallmes DF. Coil type does not affect angiographic follow-up outcomes of cerebral aneurysm coiling: a systematic review and meta-analysis. AJNR Am J Neuroradiol. 2013;34(9):1769–73.

    Article  CAS  Google Scholar 

  10. Dabus G, Hacein-Bey L, Varjavand B, Tomalty RD, Han PP, Yerokhin V, Linfante I, Mocco J, Oxley T, Spiotta A, et al. Safety, immediate and mid-term results of the newer generation of hydrogel coils in the treatment of ruptured aneurysms: a multicenter study. J Neurointerv Surg. 2017;9(4):419–24.

    Article  Google Scholar 

  11. Zhang X, Tang H, Huang Q, Hong B, Xu Y, Liu J. Total hospital costs (THC) and length of stay (LOS) of endovascular coiling versus neurosurgical clipping for unruptured intracranial aneurysms: a systematic review and meta-analysis. World Neurosurg. 2018;115:393–9.

    Article  Google Scholar 

  12. Kang HS, Han MH, Lee TH, Shin YS, Roh HG, Kwon OK, Kwon BJ, Kim SY, Kim SH, Byun HS. Embolization of intracranial aneurysms with hydrogel-coated coils: result of a Korean multicenter trial. Neurosurgery. 2007;61(1):51–8 discussion 58-59.

    Article  Google Scholar 

  13. Lanzino G, Kallmes D. Evaluation of the new HydroSoft coil in a canine model of bifurcation aneurysm. J Neurosurg. 2009;111(1):9 discussion 9-10.

    Article  Google Scholar 

  14. Ferral H. Hydrogel-coated coils: product description and clinical applications. Semin Interv Radiol. 2015;32(4):343–8.

    Article  Google Scholar 

  15. Taschner C, Chapot R, Costalat V, Courtheoux P, Barreau X, Berge J, Pierot L, Kadziolka K, Jean B, Blanc R, et al. GREAT-a randomized aneurysm trial. Design of a randomized controlled multicenter study comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment. Neuroradiology. 2015;57(6):599–604.

    Article  Google Scholar 

  16. White PM, Lewis SC, Gholkar A, Sellar RJ, Nahser H, Cognard C, Forrester L, Wardlaw JM, collaborators Ht. Hydrogel-coated coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms (HELPS): a randomised controlled trial. Lancet. 2011;377(9778):1655–62.

    Article  CAS  Google Scholar 

  17. Poncyljusz W, Zarzycki A, Zwarzany L, Burke TH. Bare platinum coils vs. HydroCoil in the treatment of unruptured intracranial aneurysms-a single center randomized controlled study. Eur J Radiol. 2015;84(2):261–5.

    Article  Google Scholar 

  18. White PM, Lewis SC, Nahser H, Sellar RJ, Goddard T, Gholkar A, Collaboration HT. HydroCoil endovascular aneurysm occlusion and packing study (HELPS trial): procedural safety and operator-assessed efficacy results. AJNR Am J Neuroradiol. 2008;29(2):217–23.

    Article  CAS  Google Scholar 

  19. Taschner CA, Chapot R, Costalat V, Machi P, Courtheoux P, Barreau X, Berge J, Pierot L, Kadziolka K, Jean B, et al. Second-generation hydrogel coils for the endovascular treatment of intracranial aneurysms: a randomized controlled trial. Stroke. 2018;49(3):667–74.

    Article  Google Scholar 

  20. Taschner CA, Chapot R, Costalat V, Machi P, Courtheoux P, Barreau X, Berge J, Pierot L, Kadziolka K, Jean B, et al. GREAT-a randomized controlled trial comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment: procedural safety and core-lab-assessedangiographic results. Neuroradiology. 2016;58(8):777–86.

    Article  Google Scholar 

  21. Raymond J, Klink R, Chagnon M, Barnwell SL, Evans AJ, Mocco J, Hoh BH, Turk AS, Turner RD, Desal H, et al. Hydrogel versus bare platinum coils in patients with large or recurrent aneurysms prone to recurrence after endovascular treatment: a randomized controlled trial. AJNR Am J Neuroradiol. 2017;38(3):432–41.

    Article  CAS  Google Scholar 

  22. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. Bmj. 2009;339:b2700.

    Article  Google Scholar 

  23. Broeders JA, Ahmed Ali U, Molyneux AJ, Poncyljusz W, Raymond J, White PM, Steinfort B. Bioactive versus bare platinum coils for the endovascular treatment of intracranial aneurysms: systematic review and meta-analysis of randomized clinical trials. J Neurointerv Surg. 2016;8(9):898–908.

    Article  Google Scholar 

  24. Cloft HJ. HydroCoil for endovascular aneurysm occlusion (HEAL) study: periprocedural results. AJNR Am J Neuroradiol. 2006;27(2):289–92.

    CAS  PubMed  Google Scholar 

  25. White PM, Raymond J. Endovascular coiling of cerebral aneurysms using "bioactive" or coated-coil technologies: a systematic review of the literature. AJNR Am J Neuroradiol. 2009;30(2):219–26.

    Article  CAS  Google Scholar 

  26. Brinjikji W, White PM, Nahser H, Wardlaw J, Sellar R, Gholkar A, Cloft HJ, Kallmes DF. HydroCoils are associated with lower angiographic recurrence rates than are bare platinum coils in treatment of "difficult-to-treat" aneurysms: a post hoc subgroup analysis of the HELPS trial. AJNR Am J Neuroradiol. 2015;36(9):1689–94.

    Article  CAS  Google Scholar 

  27. Brinjikji W, White PM, Nahser H, Wardlaw J, Sellar R, Cloft HJ, Kallmes DF. HydroCoils reduce recurrence rates in recently ruptured medium-sized intracranial aneurysms: a subgroup analysis of the HELPS trial. AJNR Am J Neuroradiol. 2015;36(6):1136–41.

    Article  CAS  Google Scholar 

  28. Raymond J, Klink R, Chagnon M, Barnwell SL, Evans AJ, Mocco J, Hoh BL, Turk AS, Turner RD, Desal H, et al. Patients prone to recurrence after endovascular treatment: periprocedural results of the PRET randomized trial on large and recurrent aneurysms. AJNR Am J Neuroradiol. 2014;35(9):1667–76.

    Article  Google Scholar 

  29. Raymond J, Roy D, White PM, Fiorella D, Chapot R, Bracard S, Kallmes DF, Icone Collaborative G. A randomized trial comparing platinum and hydrogel-coated coils in patients prone to recurrence after endovascular treatment (the PRET trial). Interv Neuroradiol. 2008;14(1):73–83.

    Article  CAS  Google Scholar 

  30. Fanning NF, Berentei Z, Brennan PR, Thornton J. HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms. Neuroradiology. 2007;49(2):139–48.

    Article  Google Scholar 

  31. Tan H, Huang G, Zhang T, Liu J, Li Z, Wang Z. A retrospective comparison of the influence of surgical clipping and endovascular embolization on recovery of oculomotor nerve palsy in patients with posterior communicating artery aneurysms. Neurosurgery. 2015;76(6):687–94 discussion 694.

    Article  Google Scholar 

  32. Brinjikji W, Kallmes DF, Kadirvel R. Mechanisms of healing in coiled intracranial aneurysms: a review of the literature. AJNR Am J Neuroradiol. 2015;36(7):1216–22.

    Article  CAS  Google Scholar 

  33. Lee S, Kang H. Statistical and methodological considerations for reporting RCTs in medical literature. Korean J Anesthesiol. 2015;68(2):106–15.

    Article  Google Scholar 

Download references

Acknowledgements

We thank all the participants for their support of this research. In addition, we are particularly grateful for Taraneh Taheri’s assistance in the completion of the language modification process of this article, from the University of Pittsburgh.

Funding

This study and analyses were supported by the National Natural Science Foundation of China (No.81571115). The funding paid staff costs for the design of the study and collection, and interpretation of data and in writing the manuscript.

Availability of data and materials

All data generated or analyzed during this study are included in this published article [and its Additional files].

Author information

Authors and Affiliations

Authors

Contributions

TX, ZC, WL, JX, XS and ZW all made substantial contributions to the study conception and design; analysis and interpretation of data; and drafting and/or critically reviewing the manuscript. TX, ZC and JX was involved in acquisition of data. TX, ZC, WL, JX, XS and ZW all reviewed and approved the final draft of the manuscript. TX, ZC, WL, JX, XS and ZW all agreed to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Corresponding authors

Correspondence to Xuming Shen or Zhong Wang.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional file

Additional file 1:

The sensitivity analysis showed that all of the consolidated results were stable. Figure S1. Fig. 3 C Sensitivity analysis of Periprocedural mortality from 4 RCTs. Figure S2. Fig. 4 A Sensitivity analysis of Mid-term complete occlusion from 4 RCTs. Figure S3. Fig. 5 G Sensitivity analysis of Mid-term mortality from 4 RCTs. (DOCX 281 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xue, T., Chen, Z., Lin, W. et al. Hydrogel coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms: a meta-analysis of randomized controlled trials. BMC Neurol 18, 167 (2018). https://0-doi-org.brum.beds.ac.uk/10.1186/s12883-018-1171-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12883-018-1171-8

Keywords